F series multi-function vector inverter 0.75KW-2.2KW

  • Product Description

Power range

▪Single phase /220V 0.75KW~2.2KW

▪Three-phase /380V 0.75KW~630KW


Features

1. Special function for photovoltaic water pump, built-in MPPT system, intelligently track the maximum power point, fast response, high stability and high efficiency

2. Special functions for water supply, compared with general water supply, multi-pump online function, antifreeze function, high and low pressure alarm, water shortage protection are added

3. Open-loop torque control mode: independent current loop control realizes real torque control, and supports online switching of torque and speed control

4. Flexible multi-stage v/f separation function, suitable for special applications

5. With 7 external input multi-function control terminals

6. 15 multi-speed control functions

7. Pulse input port 0~50KHz (up and down optional)

8. Up to 15KHz carrier frequency to minimize motor noise

9. Standard RS485 communication interface (optional)

10. Break through the limitations of inverter application, excellent performance and strong environmental adaptability

11. It has various protection functions such as overcurrent, overload, undervoltage, overvoltage, input and output phase loss, radiator overheating, etc. to meet the needs of reliable work in different occasions


Applications

▪ Textile machinery, plastic machinery, ceramic machinery, printing and dyeing machinery, pharmaceutical machinery, packaging machinery, wire and cable machinery, mining machinery, petrochemical, municipal engineering, water treatment, environmental protection equipment and other industries.


Main technical indicators and specifications

Project

Specification

Enter

Rated voltage, frequency

Three-phase 380V; 50/60Hz Single-phase 220V; 50/60Hz

Voltage Allowable Variation Range

Three-phase 320V~460V Single-phase 160V-260V

Output

Voltage

Three-phase: 0~ input voltage Single-phase: 0~ input voltage

Frequency

Low frequency mode: 0~300Hz High frequency mode: 0~3000Hz

Overload capacity

Model E: 110% long-term, 150%-min, 180% 5 seconds Model P: 105% long-term, 120%-min, 150% 1 second


Control method

V/F control, advanced V/F control, V/F separation control, current vector control


Frequency setting resolution

Analog input

0.1% of maximum output frequency

Digital setting

0.01Hz

Frequency accuracy

Analog input

Within 0.2% of maximum output frequency

Digital input

Within 0.01% of the set output frequency

V/F Control

The reference frequency can be set arbitrarily between 5~600Hz, the multi-point V/F curve can be set arbitrarily, and various fixed curves such as constant torque, low reduction torque 1, low reduction torque 2, and square torque can also be selected.

Manual setting: 0.0~30.0% of rated output

Automatic lifting: automatically determine the lifting torque according to the output current and combined with the motor parameters

No matter in the process of acceleration, deceleration or stable operation, the motor stator current and voltage are automatically detected, and they are suppressed within the allowable range according to a unique algorithm to minimize the possibility of system fault tripping

Control characteristics

Sensorless vector control

Voltage frequency characteristics

Automatically adjust output voltage-frequency ratio according to motor parameters and unique algorithm

Torque characteristics

Starting torque:

      150% rated torque at 3.0Hz (VF control)

      180% rated torque at 0.5Hz (without PG current vector control, magnetic flux vector control)

      180% rated torque at 0.05Hz (with PG current vector control)

      Steady-state accuracy of running speed: ≤ ±0.2% of rated synchronous speed

      Speed fluctuation: ≤ ±0.5% of rated synchronous speed

      Torque response: ≤ 50ms with PG vector control, without PG vector control, flux vector control ≤ 20ms

Motor parameter self-determination

Without any limitation, the automatic detection of parameters can be completed under the static and dynamic conditions of the motor to obtain the control effect

Current and Voltage Rejection

Full current closed-loop control, completely avoid current impact, with perfect over-current and over-voltage suppression function

Undervoltage suppression during operation

Especially for users with low grid voltage and frequent grid voltage fluctuations, even if the voltage is lower than the allowable voltage range, the system can maintain the longest possible running time according to the unique algorithm and residual energy distribution strategy


Product dimensions and installation dimensions

4.jpg

Voltage level

Power range(KW)

Dimensions

Installation size

Mounting Aperture (mm)

A(mm)

B(mm)

C(mm)

W(mm)

H(mm)

Simplex /220V

0.75--2.2KW

90

161

145

81

148

4

Three phase /380V

0.75--2.2KW

90

161

145

81

148

4

4.0--11KW

140

240

185

128

230

4

15--22KW

205

320

205

188

305

5

30--37KW

270

460

225

196

440

6

45--55KW

330

505

249

206

480

10

75--110KW

325

670

335

240

645

10

132--185KW

380

800

331

254

778

12

200--250KW

480

900

350

360

876

12

280--315KW

650

1060

350

500

1035

12

350--400KW

860

1200

350

640

1171

12

450--630KW

1000

1350

390

855

1323

12


5.jpg

Voltage level

Power range(KW)

Dimensions

Installation size

Floor cabinet installation

A(mm)

B(mm)

C(mm)

W(mm)

H(mm)

Three phase /380V

132--185KW

380

1200

331

/

/

200--250KW

480

1300

350

/

/

280--315KW

650

1560

350

/

/

350--400KW

860

1700

350

/

/

450--630KW

1000

1850

350

/

/


Products Recommended