V series economical inverter 0.75KW~3.7KW

  • Product Description

Power range

▪Power range:

220V: 0.75KW~2.2KW

380V: 0.75KW~7.5KW


Features

▪Easy installation, can be installed on rails

▪Compact size and low cost

▪The port is outside for easy wiring

▪Provide RS485 communication port

▪Optional pull-out keyboard

▪ V/F control; built-in PID control


Product dimensions and installation dimensions

4.jpg

power(KW)

Installation size

Dimensions

Mounting Aperture (mm)

A(mm)

B(mm)

H(mm)

W(mm)

D(mm)

0.75KW

83

145

160

95

136

5.0

1.5KW

83

145

160

95

136

5.0

2.2KW

83

145

160

95

136

5.0

3.7KW

83

145

160

95

136

5.0

5.5KW

108

200

215

120

160

5.0

7.5KW

108

200

215

120

160

5.0


Main technical indicators and specifications

Project

Specification

Input power

Phase, Voltage, Frequency

Simplex 220V 50/60Hz

Three phase 380V 50/60Hz

Voltage and frequency allowable fluctuation range

Voltage:±20%,Frequency ±5%

Input voltage lower limit

220V class: bus voltage 170V; 380V class: bus voltage 330V;

Output rating

Rated output voltage (V)

Three phase 0~220V

Three phase 0~380V

Rated overload current (%)

Type E: 150% rated output current for 1 minute, 200% rated current for 1 second, 220% rated current transient protection

Type P: 120% rated output current for 1 minute, 140% rated current for 1 second, 150% rated current for instantaneous protection

Output frequency

Rated output frequency (Hz)

50/60Hz

Maximum output frequency (Hz)

50~1000Hz Adjustable

Fundamental frequency (Hz)

20~1000Hz Adjustable

Start frequency (Hz)

0.1~10Hz adjustable, start hold time 0.0~10.0 seconds Adjustable

Carrier frequency (Hz)

0.5~15Hz Adjustable

Frequency setting accuracy

Analog setting: maximum frequency x±0.1%

Digital setting: maximum frequency x±0.2%

Control

Voltage frequency characteristics

The output voltage adjustable range corresponding to the basic frequency and the highest frequency: 320-- input voltage value

Torque boost

Automatic torque boost / manual torque boost 0.1%~30%

Starting torque

≥ 150% of rated torque at 3.0Hz (VF control mode) Torque response ≤ 50mS

≥ 180% rated torque at 1.5Hz (advanced flux vector control) torque response ≤ 20mS

Variety of ways

Linear curve, 2 square characteristic curves and multi-point VF curve

Variety of ways

Linear acceleration and deceleration, 2 kinds of acceleration and deceleration time, up to 60 hours

DC braking

Stop DC braking initial frequency: 0.0Hz~ upper limit frequency; braking time: 0.0-30.0s; braking current: 0.0%~150.0% rated motor current; voltage or current braking mode can be selected

Operation control mode

Digital operation panel, external terminal, 485 communication terminal

Frequency setting method

Digital operation panel, external analog signal 0~10V, 4~20mA, 485 communication interface


Input signal

Forward rotation, reverse rotation, external input, high speed, medium speed, low speed, reset input, analog voltage frequency command, analog current frequency command, analog control signal common terminal

Output signal

Fault alarm relay TA1, TB1, TC1 Open collector output: Y

Protective function

   

Overcurrent during acceleration

      Parameter setting error

      Motor overload torque

      Damaged brake unit

      Inverter overload

      Overvoltage during parking

      Constant speed overcurrent E2PROM fault

      Emergency pull over

      Over torque alarm

      Motor overload

      Blown fuse

      DC braking status

      Motor overload alarm

      CPU failure

      Overcurrent during parking

      Inverter overheating

      short circuit to ground

Display of operating parameters

     

Output frequency

      Output current

      Output speed

      DC bus voltage

      Output AC voltage

      Inverter temperature

      Counter

      PID target value

      PID feedback

      Operation hours

External instrument

Frequency meter, ammeter (4~20mA), voltmeter (0~10V)

Installation site

Indoor / below 1000 meters above sea level, avoid direct sunlight, non-corrosive, flammable, explosive gas, no dust, no oil mist place

Ambient temperature

-10°C to +40°C (up to +50°C when the case is removed)

Humidity

0~90% relative temperature (no condensation)

Shock

Below 0.5G

Cooling method

Fan forced air cooling

Protective structure

IP20 fully enclosed

Installation method

Wall-mounted, floor-standing cabinet


Products Recommended